2x10 HR Floor Joist Hole Repair Kit for reinforcing joist or truss holes, route utilities right through floor joists. Insert and tighten a 3/8 bolt. If you want to use nails they should probably be power driven to produce a very tight hole fit. By clicking "I AGREE" below, you are giving your consent for us to set cookies. The cut/notch happens to be right smack in the middle of the joist span. When the entire room is laid out, we snap chalk lines on the ceiling to ensure a straight and clean installation. Working in teams of two, each carpenter begins by laying out an end of the room at 16 inches on-center. In the thread on this forum "Reinforceing floor " started by "Galroc,", http://ths.gardenweb.com/forums/load/repair/msg0915531723856.html. Do you have any miracle products that can get me get one more inch of stairway head clearance? The DP34 has been tested and found suitable for tension repairs where the notch cut is from the bottom of the joist up. Notches can be placed anywhere along the length of the Joist up to 12" from supporting members.2. Ideal for new construction or resurfacing, Simpson Strong-Tie asphalt reinforcement grids are tested and proven to extend the service life of roads, highways and other heavy-use areas. The unique rolled edges of the strap allow it to span gaps as wide as 4 1/2", and its 1 1/2" width enables installation on the narrow face of 2x lumber. 4. Galvanized Predeflected Holdown with Strong-Drive SDS Screws, TP 1-13/16 in. At times when this isn't possible, shorter pieces are used instead (this is sometimes referred to as scabbing). Joist Repair Kit. The rim joist, now free floating, was all that was left to support the balloon-framed exterior wall, which had begun to slowly slide off the crumbling foundation. Ideally, the projector's projection (sorry) into the ceiling space should be boxed closely, meaning only cut out enough of the joist for the 30" required for the projector plus the two headers, and add the cut section of the joist back between the headers (in front of or behind the PJ, so the 48" becomes 34") to provide better floor support. The problem is that, in practice, joining the steel intimately to the wood is not really doable, no matter how many nails you used. Start by cutting out a small 1-2 in (2.5-5.1 cm) section of the floor joist with a reciprocating saw. CONTACT US FOR MORE INFORMATION. Straps should: be galvanised steel with a 30mm x 5mm cross-section or be in accordance with Technical Requirement R3. If you dont have access to the bottom of the joist, our product may still work. This style of framing is not correct for this type of structure. Tack a beam under the sagging joists. Jiffy Timber Joist Hangers Decking Lofts Roofing Zinc Packs - Size 41x100x75x2mm - Pack of 10. This is the last video in our th. I've attached before and after pictures (think you said you would like to see them). The unique rolled edges of the strap allow it to span gaps as wide as 4-1/2-in and its 1-1/2-in width enables installation on the narrow face of 2x lumber. Simpson Strong-Tie. This problem can be reduced by drilling the holes with the metal between the wood members and the stack clamped together. The nails are put in a shear loading, the wood is not stiff enough, and metal just slides on the surface of the wood and never gets put into a tensile load. Expamet Herringbone Galvanised Steel Joist strut, (L)600mm. Of course, the strength of this design is limited by the amount of anchorage of the steel strap but if reducing deflection by half is the goal, it works quite well. Nolan Engineering, PLLC. 10.02. 1996-2023, Amazon.com, Inc. or its affiliates, 6 Pcs Connector Straps, Steel 14-Gauge Hurricane Tie ,Hot Dip Galvanized Joist Hangers Fit 4 X Truss to Rafter Connector , for Roofing Trusses Wood Timber Connectors, 8Pcs Steel 18-Gauge Hurricane Tie ,Hot Dip Galvanized Joist Hangers Thickness 1.2mm Fit 2x Truss to Rafter Connector , for Roofing Trusses Wood Timber Connectors, 32ft Galvanized Perforated Strap Tie Strap Brace , Steel Coil Strapping 2" Width Commercial Strapping, 20 Gauge Utility Strap for Wall Studs ,Bottom of Floor Joists, Shear Wall X-Bracing, Sturdy Straps 18,800lb Lift Sling Straps 2-Pack 10 Feet x 2 Inches Long 2 Ply Heavy Lifting Straps with 11 Inch Handle. El catlogo incluye informacin sobre nuevos productos, as como especificaciones e instrucciones de instalacin aplicables para conectores estructurales de madera a madera y de madera a concreto. Simpson Strong-Tie and Structural Technologies have formed an exclusive strategic alliance to leverage each others strengths and increase their respective market share in the concrete strengthening and repair business. Composite structures put a premium on correctly dimensioned holes and compressive loading of the wood. Many of these products are approved for installation with Strong-Drive SD Connector screws. There is an engineered design report available by using the link above that can be provided to a Building Department, if required. Provides Attic Access With Limited Damage to Rafters. You can scab one or both sides of a joist, based on the reinforcement requirement. A simple, light duty joist strap with a variety of uses in building Uses Pryda Joist Strap is a simple, bent metal strap with an inbuilt nail and nail holes for fixing with 35 x 3.15 mm galvanised Pryda Timber Connector Nails. This method has been used for flitch beams to increase load rating also. 537 products Compare Sort Sort Expamet Galvanised Steel Joist hanger (W)50mm, Pack of 10 (1) 12.89 Add to basket Expamet Powder-coated Steel Joist hanger (W)50mm (1) 2.85 Add to basket Now in our 20th year, we continue to expand to provide the most comprehensive product offering to serve infrastructure, commercial, industrial and residential construction markets. Sioux Chief 524-1022PK2 3/4-Inch by 10-Feet 22-Gauge Metal Hanger Strap, TEJATAN - Straight Steel Brace (Also Known as - Straight Bracket, Straight Metal Bracket, Steel Straight Brace, Steel Straight Brackets) (Set of 10), Oatey 33923 28 Ga. Galvanized Hanger Strap, Bagged - 3/4-Inch x 10-Feet, 6 Pcs Tie Plate Bracket Flat Length 8", Carbon Steel Width 3" Metal Joint Thickness 2mm Flat Mending Repair Plate Corner Brace Heavy Duty Strap for Trusses Wood Timber, Light Gauge Steel Framing, Simpson Strong Tie LU28-25PK - 2X8 20 Gauge Face Mount Joist Hangers - Quantity 25, Simpson Strong-tie H2.5A-25PK - 18-Gauge Galvanized Hurricane Tie 25ct (25pk), 10 PCS Flat Tee Mending Plate, T Flat Repair Tie Plate, Strong T Strap Steel Right Angle Bracket, Thickness 2mm, Metal Corner Brace for Wood, Furniture, Timber Connector(Silver), 4Pcs Steel 14-Gauge Hurricane Tie , Heavy Duty Hot Dip Galvanized Joist Hangers Fit 4X Truss to Rafter Connector , Thickness 2 mm for Roofing Trusses Wood Timber Connectors, vikofan 4PCS Joist Hangers,4x6" Black Joist Hanger Fit for Beam/Swing, Cord strapping rolls for heavy packages securing, Emergency Medical Backboard Spine Board Straps. . Repair detail for TJI joists with holes too close to bearing. So, if you use the formula for simple deflection, it turns out that steel that is only 0.095 inches thick and 3.5 inches wide is just as stiff as a wood that is the same height, but 2 inches thick. SKU: HWSIJX07. To repair floor joists, the damaged joist is sistered together with a new piece of wood. This- however- doesn't mean that bridging is a superior floor reinforcement method to floor joist blocking; as the latter method also has its upsides. Copyright 2022 Simpson Strong-Tie Company, Inc. A catalog including new product information as well as any applicable specification and installation instructions for wood-to-wood and wood-to-concrete structural connectors. Scabbing. The DP34 has been tested and found suitable for tension repairs where the notch cut is from the bottom of the joist up. ", "I have to admit my fingers were crossed when the inspector went downstairs to look at the joists, which he wouldn't approve the holes on the last time he came out. Allowable loads have been increased for wind or earthquake loading with no further increase allowed. Choosing a selection results in a full page refresh. An easier way of doing this is to forget the jacking and attach a steel strap only at the beam ends and then drive a opposed wedges between the steel and the joist at mid span. It should be noted that multiple . An easy-to-use guide illustrating requirements for the repair and protection of plumbing, HVAC and electrical utilities in various building codes, and what Simpson Strong-Tie products should be used. Adding metal to the height (side) of the joist creates a quasi flitch beam, the problem that occurs is preventing buckling of the metal. If you find mildew, mold or water damage on your joists, call a plumber to find and repair any leaks you have before attempting a joist repair. AVAILABLE in US and CANADA -Please include mobile phone and email for tracking via text and email. Fastener quantities are for a single strap. Usually, the new piece of lumber spans the length of the old one. We use cookies on this site to enhance your user experience. It would also induce/force one to use a NON-slip fastening method. Here's a good rule of thumb: Notches should be no deeper than 1/6 the depth of the joist. The 2x8 DNR Joist Notch Repair Kit (Patent Pending) is a structural steel plate designed to restore the strength of Floor Joists that have been compromised due to over cut notches either at the top or bottom of the Joist. That's pretty ingenious and SIMPLE with the wedges even better if the strap can be anchored not on the bottom, but "around the corner" on the ends. (518) 280-3190 The joists are true 2x8 or thereabouts. Repair: The DP34 Deep Notch Repair Kit restores the strength of Floor Joists resulting from very deep notch cuts from the bottom of the Joist up. Ties masonry to masonry for structural (load bearing) & non-structural intersecting CMU walls. This product is manufactured from pre-galvanised mild steel classified as Euro class A1 in accordance with EN 13501-1, making it resistant to corrosive chemicals and physical impacts. Use all specified fasteners; see General Notes. Our Joist Strap is a safe way to repair the joist, created by structural engineers who know all about load-bearing requirements. B. They are flexible and pre-impregnated with bitumen to assist the installation and ensure perfect bonding between layers of asphalt. PS: DO they drive the wedges with a hydraulic jack, or just a BFHammer? The Joist Repair Strap is designed to repair notched, drilled or damaged floor joists without needing to remove any plumbing/wiring which may go through the joist. It's a great product!!!! They are not generally required at the ends of . 28-5/16-in 16-Gauge Zmax Steel Strap Wood To Wood. H2.5A 18-Gauge ZMAX Galvanized Hurricane Tie, H1 18-Gauge ZMAX Galvanized Hurricane Tie, HDU 8-11/16 in. "fall" of drain drain lines where a slop is required for proper drainage. I saw a report once that showed good results using powder actuated tools to drive nails through the flitch and clinched over.Like any other use of powder actuated tools getting sufficient impact force to drive, without over-driving, the fastener is an issue. Side Note: Being in a High-Velocity Hurricane Zone (HVHZ), and having a roofing system designed to hold concrete tiles which weigh 940-1080 lbs./square(! Simpson Strong-Tie Joist Adjustable Height Strap Hanger 440 x 150mm (H x W) is a non-welded joist hanger for supporting timber connections. If this was true even sistering would have no effect, buts it is well known to reduce bounce in floors (though it can be very hard to do if mechanicals run through the joist). Joist Reinforcers from Skyline Joist Repair are a great example of the creative, problem solving products we specialize in. Code-Compliant Repair and Protection Guide. You can see it recommended in this article http://www.taunton.com/finehomebuilding/PDF/Free/021184090.pdf, * Posted by fixizin (My Page) onWed, Apr 8, 09 at 18:30, Here is a link that might be useful: Stiffen Floors, "The key is the steel will not help if the load is already being carried by the wood.". That isn't my goal, but some aspects of the steel strapping results caught my attention. Press the space key then arrow keys to make a selection. Notches are only allowed in the first 1/3 from each end of the Joist.2. Add a bead of sealant to waterproof any gap between the rod and ledger. Set a hydraulic jack and post under the beam, and jack up the joists about 1/8 in. If the fasteners are sized and placed properly the steel strap works quite well. He signed off with no issues. admin@nolan-engineering.com, Designed by Elegant Themes | Powered by WordPress. With the sheets centered, you will have the ends of the joists exposed. They use them in shipping. The problem is that it is very difficult to fasten the steel to the wood with enough fasteners to transfer the loads to the steel. Deeply cut floor joists which leave only a small section of wood for support are a difficult problem to solve. Retirement in this Kitchen - Your Opinion, Suggestions? Attic Hatch Bulkhead. That wasn't evident in the results. Some orders that are placed early in the day may ship that day while others may not. The straps extended the entire length of the 16-foot joists, which were supported so that there was 14 feet of span. Be careful not to break the tensile strap though that can get hairy. This strengthens the joint and triangulates the roof. Joist Reinforcers from Skyline Joist Repair are a great example of the creative, problem solving products we specialize in. You need to transfer a portion of the load to the steel and fixizin describes a good way to do it. Follow. The strap is also able to restore the full strength of a drilled or otherwise similarly damage floor joist. The plates rest in or on the wall and allow for the rotted end to be cut off. To do this, a contractor will install temporary jacks to hold up and even potentially lift the floor joists. Burnt Hills, NY 12027 Here is a link that might be useful: Here is a more complete discussion. SUBSCRIBE to This Old House: http://bit.ly/SubscribeThisOldHouseS. x 4 in. To repair joist ends or replace sections call: 01626 872886 Joist End Repair Plates are supplied as pairs of galvanized steel plates, pre-drilled, to be fixed with Coach Screws (included). Watch on Purchase Download Joist Strap Design Report (PDF) Please download the engineering report for additional details. 32) Simpson 1/4" hex head structural lag style screws, 1) 3/16" drill bit for pre-drilling fastener holes. Minimum holes size still needs to be used with multiple smaller fasteners being less likely to exceed the compressive limit of the wood under load transfer. Then repeat the process to set the other end of the sistered joist to match the old joist. The average price for Metal Straps ranges from $10 to $400. SD screws are Simpson Strong-Tie Strong-Drive SD Connector screws. Model # RPS28Z. Deeply cut floor joists which leave only a small section of wood for support are a difficult problem to solve. Fasteners: Nail dimensions in the table are diameter by length. The 2x8 DNR Joist Notch Repair Kit (Patent Pending) is a structural steel plate designed to restore the strength of Floor Joists that have been compromised due to over cut notches either at the top or bottom of the Joist. Works with as little as 2" of wood remaining at the top of the Joist. The fasteners are under practically no load as long as the steel does not buckle, and of course it will not under such small deflections. (Available from NTIS as ADA013987.). That is not the case here. Discover more about the small businesses partnering with Amazon and Amazons commitment to empowering them. Any load on the gable roof above, i.e. Maximum gap between wood members is 4 1/2". This Old House general contractor Tom Silva helps a homeowner repair a cracked floor joist. im curious to hear brickeyee's response to this comment!!!!!!! Not only did the aggressive notching doom this joist, it affected the structural integrity of the floor system above. For three-part installations, install two parts on one side, one part on opposite side. Fastening the steel securely to the sides of the wood will keep the steel from buckling, and thereby increase the stiffness of the joist by an amount equivalent toe the area moment of the steel multiplied by the modulus of elasticity of steel, divided by the same for wood. a day until they're level. Prevention: Do not lap strapping over the joist flanges. For 9 1/2" LP I-Joists with 1 1/2 " flange width and height. Scabbing is a simple and affordable yet effective joist reinforcement method. http://www.homebuildingandrepairs.com/repairs/framing/index.html Click on this link for more information about home repairs. I was enthused about this approach for a problem with my own house until I came across a paper by the Corps of Engineers titled "Evaluation of Expedient Techniques for Strengthening Floor Joist Systems in Residential Dwellings." Our patented Joist Reinforcers are just the ticket when it comes to running utilities through wood joists while maintaining code compliance. Click Here for the product design report provided by Nolan Engineering, PLLC. Add to basket. Ceiling Joists Please contact us directly if you have any concerns if this product is the correct solution for you.**. Notch width cannot exceed 1/3rd of the depth of the Joist.With a Joist Reinforcer1. Like you said, I handed him the Intertech Report. The DP24 has been tested and found suitable for tension repairs where the notch cut is from the bottom of the joist up. Assuming the joists are in good condition, the solution to both sagging and bounciness problems is to reinforce the floor. 415 Elm Ave SWRoanoke VA 24016540-589-9669 dan@joistrepair.com, Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device, Same day shipping on orders placed Mon-Fri before 3pm. Thank you for your help". We will continue to expand upon this line of repair, protection and strengthening products and provide our customers with industry leading jobsite, technical and customer support. Adding steel at the BOTTOM of the joist THEORETICALLY increases the area moment, ONLY if the steel is jointed intimately to the wood, thereby putting x-section of the steel in pure tension. This can cause it to rub against a popped nail. Jacking up the beam would not prestress the assembly unless the steel is installed straight and level while the center of the beam is jacked up above level and shims are installed to keep them that way. "jacking up") the joist to a neutral--or even negative--deflection, THEN securely/intimately attaching the steel? Descriptions: The 2810HR Joist Reinforcer allows the placement of a 6" diameter hole in a 210 or 212 wood joist and a 4" diameter hole in a 28. "Those joist reinforcers worked fantastic! A while back, I considered completing a task that had been on my to-do list for ages - fixing my bouncy living room floor. The CTS218 is designed to repair wood members such as top plates, studs and trusses, and it handles both tension and compression loads. for pricing and availability. Steel strapping is a way to stiffen an already installed joist.A test to failure is not meaningful here. - Terry Evinger, Bothel, WA, "The joist reinforcers worked great! Works with as little as 2" of wood remaining at the top of the Joist. Cast Iron sink in an Ikea cabinetnon apron. The Simpson Strong-Tie CI family of crack repair products has a solution for almost every job. That for the steel reinforced joists was calculated to be 512.5 inches^4. The moment of inertia of the three 2 x 10 southern yellow pine joists used for a test section was calculated to be 296.8 inches^4. 415 Elm Ave SWRoanoke VA 24016540-589-9669 dan@joistrepair.com, Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device, Same day shipping on orders placed Mon-Fri before 3pm, CALL FOR QUANTITY DISCOUNTS - 540-589-9669, Feel free to call, text, or email 24/7 customer service if you have questions. What building codes allow for notch cuts in Floor Joists (without Joist Reinforcer) 1. Call us at 540-589-9669. ), I probably have the most serious type of mass-produced roof trusses, and the steel components are all attached to the SIDES (BOTH SIDES) of the 2x6 and 2x4 lumber components, none to the bottoms/edges FWIW. The better approach would be to install steel on the SIDES of the joist, oriented vertically. Each kit consists of a steel strap that is ideally screwed to the bottom of the floor joists. The key is the steel will not help if the load is already being carried by the wood. Installation Instructions and Eng Report. The top-selling product within Metal Straps is the Simpson Strong-Tie H2.5A 18-Gauge ZMAX Galvanized Hurricane Tie. I wonder what they measure for flitch beams?They will fail with oversize holes also. The strap is wide enough to increase the contact area and provide improved nail spacing to enhance the performance of . Replacing some part with a piece fastened on, such as a steel strap on the bottom, is really making it into a composite joist. Joist Reinforcers from Skyline Joist Repair are a great example of the creative, problem solving products we specialize in. Pros Cons; Cost to sister floor joists: $100 - $300 per joist: Cost to replace floor joists: $6,000 - $10,000+ Outdoor Accents Mission 11-1/4-in 12-Gauge Powder-coated Steel Strap Wood To Wood. ;'), We have a winner! Notch can be up to 6" wide. I was able to achieve my remodel as intended and it's already closed up and finished. This is a very old method of reinforcing floor joists. The DP24 works for notches up to 6" wide. Call us at 540-589-9669. Our product provides an affordable, alternative solution to sistering the joist in order to restore the integrity of the joist and promote safety. Bearing End Replacement Use For use to replace rotted ends or as splicing plates to add a new length of timber Supplied as pairs of galvanized steel plates, pre-drilled, to be fixed with Coach Screws (included). Each of these products have passed the performance and quality assurance protocols that are expected of Simpson Strong-Tie, and have been selected to address the unique challenges of Commercial Retrofit, Bridge and Marine and Water/Wastewater projects. Bounce occurs when additional transient loads (like walking) cause even more deflection. The moment of inertia of the three 2 x 10 southern yellow pine joists used for a test section was calculated to be 296.8 inches^4. Choosing a selection results in a full page refresh. Certainly screws as you described in one of the other threads on this subject would help overcome this. Thankfully the existing rim joist was an 8x8 beam. Asphalt Pavement Reinforcement Solutions Now you can build roads that are stronger and more economical. Certainly you will get more tension if you insall straight and level with end attachment only and then drop the beam, but even jacking up the beam and installing from a central nail in firm contact with the joist will prestress by the difference in elongation between the compressed state of the joist when deformed into an upward deflection, and the tensed state when it drops. Allowable TJI Joist Rafter End Cut. The CTS218 is designed to repair wood members such as top plates, studs and trusses and is our first strap that handles both tension and compression loads. The difference in bottom chord length is very much measurable. The same holds true if you see termite tunnels, sawdust piles or other signs of insect activity. Flat T Shape Large Tee Repair Plate Bracket Mending Fixing Corner 70x50x20mm - Pack of 20. Fixing A Damaged Floor Joist Extreme How To. Repairs Bowing Foundation Walls. Depending on cost and practicality, they could mean beefing up the floor joists, or adding new support underneath with new or reinforced posts of support beams. The unique rolled edges of the strap allow it to span gaps as wide as 4 1/2", and its 1 1/2" width enables installation on the narrow face of 2x lumber. Joist Reinforcers from Skyline Joist Repair are a great example of the creative, problem solving products we specialize in. However, while the measured moment of inertia for the unreinforced joists was 300.4 inches^4, very close to the calculated value, that for the steel strap reinforced joists was only 324.4 inches^4, a very modest increase for a lot of work. Please download the engineering report for aditional details. The lag screws included are 1/4" by 1, 1/2" and will protrude out about an 1/8" from the steel. i-Joist Web Reinforcer Repair Kit - 1.5in, 2.5in, 3.5in flange width 9.5in, 11.875in, 14in, and 16in height. What is the top-selling product within Metal Straps? 4. The Joist Repair Strap is designed to repair notched, drilled or damaged floor joists without needing to remove any plumbing/wiring which may go through the joist. The DP24 provides the solution with heavy duty steel and structual fasteners that more than make up for the lost support. 540-589-9669 | dan@joistrepair.comFor availability in other countries please call - 540-589-9669, Notch Reinforcer Installation InstructionsScrews, Drills, and Drivers. Simpson Strong-Tie Adjustable Height Joist Hanger Strap 75mm (W) is an industry standard timber hanger for solid joists made of mild steel that is galvanized to provide durable support with ease of installation. Outside Diameter), CS 25 ft. 16-Gauge Galvanized Coiled Strap, HTT 16 in. The DP30 will repair a notch up to 16" wide. The DP34 Deep Notch Repair Kit restores the strength of Floor Joists resulting from very deep notch cuts from the bottom of the Joist up. When the joist repair strap is installed at the bottom of a notched floor joists, the strap transmits the tension load that is generated back into the remaining wood at either side of the notch. PrivacyPolicy. Well, at least not on the joist holes. When renovating a building, you might be challenged by floor joists that have been cut to allow for pipes or conduits to pass through, or you may be considering cutting existing joists to install new plumbing or conduits. The DP30 provides the solution with heavy duty steel and structual fasteners that more than make up for the lost support. Solid blocking should be used where floor joists overlap over beams. Floor Joist Repair Cost for a 500-Square-Foot Room. Structural engineers, contractors and infrastructure owners have chosen our companies for their concrete and masonry strengthening and repair projects because of our innovative, value-engineered products, designs, expert installation methods and dedicated customer support. Skyline Joist Reinforcer solutions are strongest and Reinforcers made for routing plumbing, wiring, and HVAC right through floor joists. PrivacyPolicy. Press the space key then arrow keys to make a selection. Be the first to know about new collections and exclusive offers. Repairs Cut, Notched, or Damaged Floor Joists. Intuitively, pre-stressing *seems* like the way to get the most "balanced" strength out of both materials yes/no? respondent "brickeyee" provided considerable information on the approach of adding steel strapping to the underneath of the joist. Standard (IBC) Size: 16 gauge - 1/2 sq x 6 x 14 Other sizes available - Call 1-800-659-4731 or sales@masonpro.com Finish: Hot Dip Product Data Sheet SDS Hot Dip LEED Purchase Online Intersecting CMU Walls (Flange Action - Shear Transfer): Z-Strap Ideal for new construction or resurfacing, Simpson Strong-Tie asphalt reinforcement grids are tested and proven to extend the service life of roads, highways and other heavy-use areas. Find My Store. After running the bolt or rod from the inside out through the ledger, position the deck-joist hardware and screw it in place. We strap the ceilings after all ceiling and bearing-wall framing is finished.
Small Knotless Braids,
Commercial Fishing License Louisiana,
Why Did Aveda Discontinue Black Malva,
Everett High School Basketball Roster,
Jack Saadia Saadia Group,
Articles J